Ecler MPA 4-400R User Manual

Page 9

Advertising
background image

9

3.5. Input options

1 mono

4 mono amplifiers for 4 different mono signal

2 mono

4 mono amplifiers for a common mono input

3 mono

4 mono amplifiers for a common stereo input

4 stereo

2 stereo amplifiers for 2 different stereo inputs

5 stereo

2 stereo amplifiers for a common stereo input

6 bridged

2 bridged amplifiers for 2 different mono signals

7 bridged

2 bridged amplifiers for a common mono signal

8 bridged

2 bridged amplifiers for a common stereo signal

9 combination 1 bridged amplifier and 2 mono amplifiers for a common mono input

10 combination 1 bridged amplifier and 1 stereo amplifier for 2 different stereo inputs
11 combination 1 bridged amplifier and 1 stereo amplifier for a common stereo input

INPUT SIGNALS

INPUT SELECTORS

MODE ST-BR

N.

1 2 3 4

CH1

CH2

CH3

CH4

CH1-2 CH3-4

1 I1 I2 I3 I4

IN1

IN2

IN3

IN4

ST

ST

2

I

-

-

-

IN1

LINK CH1

LINK CH1

LINK CH2

ST

ST

3

L

R

-

-

IN1+IN2

LINK CH1

LINK CH1

LINK CH2

ST

ST

4 L1 R1 L2 R2

IN1

IN2

IN3

IN4

ST

ST

5

L

R

-

-

IN1

IN2

LINK CH1

LINK CH2

ST

ST

6 I1 - I2 -

IN1

-

IN3

-

BR

BR

7 I - - -

IN1

-

LINK

CH1

-

BR

BR

8 L R - -

IN1+IN2

-

LINK

CH1

-

BR

BR

9

I

-

-

-

IN1

LINK CH1

LINK CH1

LINK CH2

BR

ST

10 L1 R1 L2 R2

IN1+IN2

-

IN3

IN4

BR

ST

11 L

R

-

-

IN1+IN2

IN2

LINK CH1

LINK CH2

BR

ST



3.6. Limiter circuit

This system is an always active protection inside the MPA R series of amplifiers. The ANTICLIP

circuitry constantly analyses harmonic distortion caused by excessive signal excursion at the power
amplifier's output and automatically reduces the input level in order never to reach distortion. The
MPA4-400R amplifiers are delivered with the anticlip system adjusted at a threshold of 1% THD (hard
limiting). However, this value can be switched to a softer limiting (5% THD) via an internal jumper (see
diagram).

The great convenience of such a circuit in any kind of installation has to be remarked: The clear

advantage of a limiting system in front of conventional compressors is that the former does practically not
alter the dynamic range, acting only when the distortion threshold is reached.


CAUTION: Changes on the ANTICLIP configuration have to be performed by a qualified
technician.

Advertising