White paper – networking with eclernet manager, Advanced network configuration – Ecler White Paper - Networking with EclerNet Manager User Manual

Page 5

Advertising
background image

 

 

 

White Paper – Networking with EclerNet Manager 

Document:  AS

Version:  1.0

Date:  

Page 5 of 12

Care must be taken to enter the IP address without leading zeros, since: 

10.0.0.

0

Is definitely not the same as: 

10.0.0.4 

A UDP port is used by EclerNet Manager software and its compatible hardware to send control 
and data messages between devices. So, an extra care must be applied to ensure that all the 
network devices between the controller (PC) and the controlled (MIMO88) devices allow UDP 
packets to flow freely; this can affect to switches, hubs, routers etc. The UDP port value can be 
changed to any suitable and unused value, but must be done at both sides simultaneously. 

A basic and useful tool is the “ping” command. Always check the correct configuration pinging 
from the PC to the device IP address (again, from a CMD window): 

 

 

More advanced tools to help in troubleshooting are the port scanners and the traffic network 
analyzer such Nmap, Wireshark… 

  

3. Advanced Network Configuration 

 

EclerNet Manager uses multicast packets to “discover” the unused compatible devices (those 
ones still not included in a project), even if they are not in the same IP range. These devices 
may appear inside the “Online and Unused Devices List” window in EclerNet Manager: 

 

Advertising