To Start the Engine:
• Ensure that tank is positioned properly (arrow

up).

•

Turn on main valve on tank.

•

Check all connections for tightness and inspect for leaks.

• If you detect a gas odor immediately shut off the main fuel valve and consult a qualifi ed LP-gas service person or
call EDCO durectly. NEVER allow propane to escape in an enclosed area; propane is heavier than air and will
“settle”.
•

Make sure E-STOP switch is in ON position.

•

Push and hold primer button until gas stops fl owing.

•

Open throttle completely.

•

Tilt machine back slightly.

•

Push START button.

•

Adjust throttle to idle and sit machine back on surface.

•

Increase speed to operating position.

To Stop the Propane Model:
NOTE: If engine stops abruptly (uncontrolled stop) or using E-STOP wait several minutes for propane gas to
clear the fuel system and carburator before trying to re-start.
•

Tilt the machine back slightly to allow the disc to clear the slab surface.

•

Close the valve on the propane tank.

•

Turn the engine off.

Propane Models:

(13 HP Kawasaki Engine with 115V Electric Start)

Propane is extremely fl ammable.

Electric Models:

(5 HP Baldor. Available in 1 Phase or 3 Phase)

Gasoline Models:

(11 HP Honda Engine)

To Start the Engine:

•

Tilt the machine back slightly to allow the disc to clear the slab surface.

•

Start the engine according to the directions in the engine manufacturer’s Owner’s Manual.

NOTE: If during operation refueling becomes necessary, allow the engine to cool down. NEVER refuel a hot engine.

To Stop the Gasoline Model:

•

Tilt the machine back slightly to allow the disc to clear the slab surface.

•

Turn the engine off.

To STOP engine

Press Emergency Stop Switch to OFF position

Press to ON position when re-starting Engine

(Figure 3)

Figure 3

Electric units must be connected to a properly grounded
electrical system using an approved electrical cable.