EVCO EVF815P9 User Manual
Page 56
Advertising

EVCO S.p.A.
EVF815 | Installer manual ver. 1.2 | Code 144F815E124
page 56 of 60
Digital outputs:
5 outputs (electromechanical relays):
-
1 SPST (K1) 30 A res. output @ 250 VAC for compressor
management
-
2 x 16 A res. outputs @ 250 VAC of which one SPDT (K2)
for management of defrosting and one SPST (K4) for
management of the door heating elements or of the
condenser fan
-
2 x 8 A res. outputs @ 250 VAC of which one SPST (KS) for
management of the evaporator fan and one SPDT (K5) for
management of the cabinet light, needle probe heating or
the UV light.
Type of actions and complementary
features:
1C.
Communication port:
1 TTL serial port with MODBUS communication protocol
Advertising