WORK SETPOINT AND CONFIGURATION PARAMETERS

14.1 Work setpoint

MIN.

MAX. U.M.

DEF.

r1

r2

°C/°F (1) 0

r7

r8

°C/°F (1) 0

14.2 Configuration parameters
PARAM. MIN.

MAX. U.M.

DEF.

SP1

r1

r2

°C/°F (1) 0

SP2

r7

r8

°C/°F (1) 0

PARAM. MIN.

MAX. U.M.

DEF.

CA1

-25/-50 25/50 °C/°F (1) 0

CA2

-25/-50 25/50 °C/°F (1) 0

P0

0

1

- - -

0

P2

0

1

- - -

0

P5

0

1

- - -

0

P6

0

1

- - -

0

P7

0

1

- - -

0

PARAM. MIN.

MAX. U.M.

DEF.

r0

1

99

°C/°F (1) 2

r1

0

r2

°C/°F (1) 0

r2

r1

999

°C/°F (1) 260

r6

1

99

°C/°F (1) 2

r7

0

r8

°C/°F (1) 0

r8

r7

999

°C/°F (1) 260

r12

0

1

- - -

0

r13

0

240

min

240

r14

0

1

- - -

0

PARAM. MIN.

MAX. U.M.

DEF.

t0

0

1

- - -

0

t1

0

250

s

1

t2

1

250

ds (4)

10

PARAM. MIN.

MAX. U.M.

DEF.

c4

-1

120

s

-1

c5

0

60

min

0

c6

0

60

min

0

c7

00:00 60:00 min:s

60:00

c8

0

1

- - -

1

c9

0

120

s

10

c12

0

999

min

60

PARAM. MIN.

MAX. U.M.

DEF.

A1

0

999

°C/°F (1) 200

A2

0

240

min

0

A3

0

2

- - -

1

A4

0

999

°C/°F (1) 300

A5

0

240

min

0

A6

0

2

- - -

1

PARAM. MIN.

MAX. U.M.

DEF.

LA

- - -

- - -

- - -

- - -

Lb

- - -

- - -

- - -

- - -

LP

- - -

- - -

- - -

- - -

(1)

the unit of measurement depends on parameter P2

(2)

set the parameters relative to the regulators appropriately after modification of parameter P2

(3)

if the power supply cut-off is shorter than the time established with parameter r13, the count will also continue when the instrument is not powered

(4)

ds = tenths of second

(5)

the parameter differential is 10 °C/18 °F.

WORK SET-POINT
top set-point
floor setpoint

WORK SET-POINT
top set-point
floor setpoint
MEASUREMENT INPUTS
top probe offset
floor probe offset
type of probe
0 = J
1 = K
temperature unit of measurement (2)
0 = °C
1 = °F
quantity shown by the highest display during the on state or during normal functioning
0 = temperature of the top
1 = top set-point
quantity shown on the central display during the on state or during normal functioning
0 = temperature of the floor
1 = floor setpoint
quantity shown by the lowest display during the on state or during normal functioning
0 = value of the cooking timer or its count if the timer is active
1 = real time
MAIN REGULATOR
top set-point differential
minimum top setpoint
maximum top set-point
floor set-point differential
minimum floor set-point
maximum floor set-point
restraint between the top output and the cooking timer
1 = YES - the top output remains off if the cooking timer count is not in progress
duration of a power supply cut-off duration that occurs during a cooking timer count exceeding which the count is interrupted (3)
restraint between the floor output and the cooking timer
1 = YES - the floor output remains off if the cooking timer count is not in progress
STEAM INJECTION
steam injection functioning mode
0 = pressing the key causes the injection of steam for the time established with parameter t2 or for the entire duration that the key is pressed. The parameter t1 establishes

the minimum time that can pass between the two successive injections

1 = pressing the key enables automatic injection of the steam in cyclical mode (parameter t2 establishes the switch-on duration of the injector and parameter t1 establishes

switch-off duration)

if t0 = 0, minimum time that passes between two successive injections
if t0 = 1, injector switch-off duration
if t0 = 0, minimum injection duration
if t0 = 1, injector switch-on duration
VARIOUS
duration of buzzer activation on conclusion of the cooking timer count; see also c9
-1= the buzzer must be deactivated in manual mode by pressing a key
time that passes between the activation of the airhole and the conclusion of the cooking timer count, see also c6
duration of the activation of the airhole at conclusion of the cooking timer count, see also c5
duration of the activation of the airhole in manual mode
displays the day of the week and the real time respectively in the central display and the lowest one during the stand-by status
1 = YES
time that passes between the activation of the buzzer and the conclusion of the cooking timer count, see also c4
time that must pass (from programmed switch-on of the instrument) without having operated on the keys so that the instrument passes to the programmed switch-on state again
0 = no function
TEMPERATURE ALARMS
top temperature above which the top temperature alarm is activated; see also A3 (5)
top temperature alarm delay
type of top temperature alarm
0 = no alarm
1 = absolute (i.e. A1)
2 = relative to the top set-point (i.e. “top set-point + A1”)
floor temperature above which the floor temperature alarm is activated, se also A6 (5)
floor temperature alarm delay
type of floor temperature alarm
0 = no alarm
1 = absolute (i.e. A4)
2 = relative to the floor set-point (i.e. “floor set-point + A4”)
RESERVED
reserved
reserved
reserved