How to order – EVCO EC6145 User Manual
Page 2

Power supply:
230 Vac or 115 Vac or 24 Vac or 12-24 Vac/dc or
12 Vac/dc, 50/60 Hz, 5 VA.
Insulation class:
II.
Measure inputs:
2 (cabinet and evaporator probe) for PTC/NTC probes.
Digital inputs:
1 door switch (5 V, 1 mA) configurable to interact on the
outputs activity and for NO or NC contact.
Display:
green LED diode Ø 3 mm (0.11 in.) instrument status indi-
cator.
Outputs:
four NO contact relays of which one 16 (3) A @ 250 Vac
relay for one 1½ HP @ 250 Vac compressor management
and three 8 (3) @ 250 Vac relays for evaporator fans, de-
frost system management and for cabinet light control.
HOW TO ORDER
CODING SYSTEM
Instrument name:
EC 6-145.
Desired measure input:
P (for PTC/NTC probes).
Desired power supply:
220 (230 Vac)
115 (115 Vac)
A24 (24 Vac)
024 (12-24 Vac/dc)
012 (12 Vac/dc).
2