Installation
Your new mixer is supplied partially assembled. For 
more information, see the parts list pages for general 
arrangement drawings. 
 
 
Impellers: 
To install the impeller, back off the set screw as far as 
possible without removing them. Insert mixing shaft 
into the bore and tighten the set screw firmly to secure 
the impeller to the shaft. 
 
 
 
 
Impeller Placement: 
Begin by mounting it I to 2 impeller diameters distance 
off the bottom of mixing container. 
 
The above guideline is a “rule of thumb” and may not 
be the best for your situation. Experimenting with 
impeller placement may provide your best results. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Assembly: 
1.) Assemble stand rod to base. 
2.) Insert the “L” mounting block onto the base 
stand rod and tighten the “T” handle.
3.) Insert the powerhead with mounting ring into
the “L” block.
4.) Adjust the powerhead to the desired height
and tighten the “T” handle.
5.) Assemble air hose to inlet port. 
6.) Make sure air control valve is closed. 
 
Mixer is now ready to operate. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 