1.

Make sure the communication settings in the reader are configured as below.

To enter communication settings follow the steps below:

MENU > OPTION > COMM OPT

Baud Rate

115200

Dev Num

1

IP Add

192.168.1.201

Net Speed

10M-F

Ethernet

Y

RS232

N

RS485 N

Comm Key 0

2.

The IP address set in the reader must be the same as set in software. Example:


In WAC 101

192.168.1.201

In TCMS v2 software

192.168.1.201

After setting up the IP address, try to test the connection by using “ping”

command.
Open

MS-DOS-PROMPT in windows program, enter ‘ping 192.168.1.201’

(or other IP address configure in the device). If the connection is fine then

device will reply to the computer. An example the result will show as below: