Dimensions and data

The table below shows maximum allowed lateral displacement for the
different capacities of rubber elements and the restoring force created by the
rubber at this displacement. The force is linearly proportional to the displacement.
If side forces exceeding RF are expected, external bumper stops must be
arranged.

* Including spacer.
** S

max

=maximum lateral displacement of load carrier.

*** RF =restoring force at S

max

.

All dimensions in mm. Dimensions and specifications are subject to change without notice.
CAD files for customer’s own applications drawings are available on request.

Load Cell Type

Capacity in kg

L

H1

H2

W1

W2

Mounting

bolts D

S

max

**

RF***

at S

max

SB4/SB5-5/10/20 kN

510/1020/2039

180

63

12

80

58

M8

5 mm

1600 N

SB4/SB5-50 kN

5099

219

78

15

100

76

M10

5 mm

5000 N

SB6-200 N/500N/
1 kN/2 kN

20.4/51/102/204

150 65*

10

60

44

M6

6 mm

700 N

SB14-500 lb

227

154

54

10

60

44

M6

6 mm

700 N

SB14-1/2.5/5 klb

454/1134/2268

164 60*

12

80

58

M8

5 mm

1600 N

SLB-200 lb/500 lb

91/227

154 55*

10

60

44

M6

6 mm

700 N

SLB-1/2.5/5 klb

454/1134/2268

164 59*

12

80

58

M8

5 mm

1600 N