Flintec, Lac 65.1, The right weigh – Flintec LAC 65.1 User Manual

Page 2: System configuration, Lac 65.1 specifications

Advertising
background image

...the right weigh

FLINTEC

Page 2

Manual LAC 65.1

FLINTEC

LAC 65.1

Int.PWR.ON

5

10

20

40

80

160

320

0-3

2,5

5

10

20

40

+/-

1-2

2

4

8

16

32

0-20/4-20

mA

Overflow

-/+

Rel.Gain(x)
SET SPAN

% of FS-in

SET ZERO

(ms)

L-P-FILTER

t

OFF

ON

1A

SUPPLY PWR.

12-24 VDC 3W

Galvanically isolated

V

2,5V 425Hz <60mA

EX

Load Cells

OUTPUTS

+/-10V 20mA

+ +

0 0

+

+

+

-

-

-

Vo

Io

Exc Sen Sig Sig Sen Exc

PLC and/or

computer with

analogue input

Load cells

6-wire

connection

;

PLC

system

Silo Nr.:

1

Netto

: 17285 kg

Tara

: 1458 kg

Power supply

-----------------------

12...24 V DC

System Configuration

Linearity

< 0.01 %

Analogue input range

± 0.17 mV/V to 3.3 mV/V, gain adjustment by DIP switches and fine trimming
potentiometer

Excitation

2.5 V AC 425 Hz, for up to 8 off 350 Ohm load cells
active sense for cable length up to 100 m

Zero adjustment (Offset)

±80%, zero adjustment by DIP switches and fine trimming potentiometer

Current output

0 ... 20 mA or 4 ... 20 mA, R

load

³

500 Ohm

Voltage output

0 ... ±10 V, R

load

³

500 Ohm

Active filtering 40 dB / decade

0.25; 0,5; 1; 2; 4; 8; 16; 32 Hz selectable

Temperature range

–20 °C to +50 °C, storage –20 °C to +60 °C

Temperature effects

on zero

30 ppm/°K

on span

15 ppm/°K

Housing

114 x 78 x 16 mm, protection IP40, for standard 35 mm DIN-rail mounting

Power supply

12 … 24 V DC +10 / –15%, C, 3 W max., galvanically isolated

All dimensions in mm. Dimensions and specifications are subject to change without notice.