Haltech E6S User Manual

Page 13

Advertising
background image



13

•

Engine Speed Pickup

Compatible with most trigger systems:

- 5 or 12 volt square wave;

- pull-to-ground (open collector)

Tach adaptor available for magnetic (or ‘reluctor’) triggers

ECU Outputs

•

Injector Driver


E6S

4 x 4/1 Amp peak-and-hold current limiting drivers:

- up to four low-impedance injectors*

- up to eight high-impedance injectors*

(Expandable using optional Driver Box. See Appendix C)

E6S - 8

8 x 4/1Amp peak-and-hold current limiting drivers:

- up to eight low-impedance injectors*

- up to sixteen high-impedance injectors*

(Expandable using optional Driver Box. See Appendix C)

•

Ignition Output

Haltech Ignition Module, trigger by ECU, for directly firing the coil.

(may also be compatible with other igniters. Ask your Haltech dealer.)

•

Fuel Pump Control

20A fused relay, features automatic priming and switch-off.



* additional hardware may be required

System Programming Requirements

•

Computer

IBM-PC or compatible, preferably laptop or notebooks

CGA, EGA or VGA, colour or monochrome display

640+ kb RAM

•

Disk Drive

3.5" Floppy Disk Drive

(5.25" disk available on request)

•

Serial Port

Standard RS232C port - 9 pin D connector

(25 pin cable available on request)

COM1 or COM2 (selectable)