E6GMX Manual

71

- The Digital Outputs and PWM Outputs are functionally described in the

table below. In some applications the Digital Outputs may be used for fuel
or ignition and will not be available.


- The

O

2

Closed Loop Control uses the input signal on the O2 pin for O2

corrections only.

-

For the Aux In functions refer to 4.2.5 The In/Out Set-up Page, p35

General Purpose Outputs

Output Description

Digital Out 1–2

PWM 1 – 4

Turbo Wastegate

NO

•

Bypass Air Control (BAC)

NO

•

Dual Intake Valve

•

•

Torque Converter Control

•

•

Thermofan

•

•

Intercooler Fan

•

•

Shift Light

•

•

Aux Fuel Pump

•

•

Stall Saver

•

•

Staging Signal

•

•

Turbo Timer

•

•

NOS Switch

•

•

Anti-Lag Switch

•

•


For further detail on the operation of the PWM outputs and digital outputs refer to CHAPTER
11 Digital Outputs & PWM Outputs, p77
.