131
Figure 5: Typical 6 cylinder/ 3 rotor application
8 Cylinder
For an eight cylinder 5 magnets are required in total positioned exactly 90
°
apart. A south
pole needs to trigger the sensor before the trigger for cylinder No 1.
Figure 6: Typical 8 cylinder application
The ignition set-up for the S2 needs to be configured in the following way:
Trigger Edge: Falling
Trigger type: Standard
Home Edge:
Falling or Rising