Inverter Coolant

Ma

inte
na
n

ce

Inverter Coolant

This coolant is premixed with 50% antifreeze and 50% water. Do not add any
straight antifreeze or water.

We recommend you check the inverter coolant level every time you refuel. Check
the filler tank. Add the inverter coolant accordingly.

Have a dealer replace the inverter coolant.

1. Check the amount of coolant in the filler

tank.

2. If the coolant level is below the MIN mark,

add the specified coolant until it reaches
the MAX mark.

3. Inspect the cooling system for leaks.

Specified coolant: Honda Long Life Antifreeze/Coolant Type 2

Checking the Coolant

1

Inverter Coolant

NOTICE

If temperatures consistently below −22°F (−30°C) are
expected, the coolant mixture should be changed to
a higher concentration. Consult a dealer for more
information.

If Honda antifreeze/coolant is not available, you may
use another major brand non-silicate coolant as a
temporary replacement. Check that it is a high quality
coolant recommended for aluminum engines.
Continued use of any non-Honda coolant can result
in corrosion, causing the cooling system to
malfunction or fail. Have the cooling system flushed
and refilled with Honda antifreeze/coolant as soon as
possible.

Do not add rust inhibitors or other additives to your
vehicle's coolant system. They may not be compatible
with the coolant or with the motor components.