Refueling Procedure

5. Securely connect the CNG fill

nozzle to the fuel receptacle by

turning the lever until the arrows

on the nozzle point to each other.

6. Follow the instructions on the

refueling station to begin refueling.

While refueling, you may hear a

chattering sound. This is normal.

If you hear fuel leaking from the

nozzle-receptacle connection, stop

refueling immediately. Dirt or

other debris may be preventing a

positive connection. Turn off the

refueling station, remove the

nozzle, reconnect it to the

receptacle, and begin refueling

again. If it continues to leak, have

an authorized Honda Civic GX

dealer inspect the sealing 0-ring in

the receptacle for damage and

wear.

7. Refueling will stop automatically

when the tank is full. Follow the

instructions on the refueling

station to turn it off.

8. Disconnect the CNG fill nozzle

from the fuel receptacle by

turning the lever on the nozzle 180

degrees. You may hear a brief

hissing sound as a small amount of

gas escapes. This is normal.