Wiring the power input – Interlogix NS3550-8T-2S Installation Guide User Manual

Page 5

Advertising
background image

5

Wiring the Power Input

The 6-contact terminal block connector on the rear panel of NS3550-8T-2S is used for two DC redundant powers inputs. Please

follow the steps below to insert the power wire.

1.

Insert positive / negative DC power wires into contacts 1 and 2 for DC POWER 1, or 5 and 6 for DC POWER 2.

2.

Tighten the wire-clamp screws to prevent the wires from loosening.

1 2 3 4 5 6

Power 1

Power 2

- + - +

The wire gauge for the terminal block should be in the range of between 12 ~ 24 AWG.