Step 1—Inspect Package and Check Equipment

Inspect contents of packaged humidifier. File claim with shipping
company prior to installation if shipment is damaged or incom-
plete.
The package should contain:

1. Humidifier and media assembly

2. Humidistat

3. Template

4. Owner’s Manual

5. Warranty Certificate

6. Solenoid valve with bridge rectifier

7. Saddle valve assembly with adapter

8. Four sheet metal screws

9. Foam tape

10. Water noise reducer (use for water pressure over 60 psi)

11. 6-in. damper

12. Worm clamp for field-supplied drain tube

13. Humidifier maintenance instruction sticker

14. Carrier logo label

Step 2—Select Location (See Fig. 1.)

Humidifier may be installed on either supply or return plenum.
If furnace has air conditioning coil, be sure humidifier does not
interfere with coil ends. Remember to provide clearance for
maintenance and evaporator pad removal.

Step 3—Prepare Plenum Opening (See Fig. 2.)

1. Use template for marking humidifier opening.

2. Tape in place on plenum making sure template is level.

IMPORTANT:

For humidifier to operate properly it must be level

and mounted on a vertical surface.

3. Drill four 1/8-in. holes in plenum.

4. Cut opening in plenum using heavy solid lines on template as

a guide.

Step 4—Mount the Humidifier (See Fig. 3.)

1. Attach foam tape on inside of mounting flange.

2. Hook bottom notch of humidifier on opening cut in plenum.

3. Push top of humidifier to plenum aligning screw holes with

flange.

4. Align, level, and secure using top screws first.

5. Insert bottom screws and tighten all screws for air tight seal.

Step 5—Install Bypass Duct

Attach field-supplied 6-in. diameter duct, elbow, or starting collar
with field-supplied 1/4-in. zip screws. Install supplied 6-in. damper
in 6-in. duct connector.

IMPORTANT:

On systems with central cooling, the damper

should be closed during cooling season to prevent bypass air.

Do not support weight of bypass duct from humidifier —
damage could result.

Step 6—Install Drain Line

1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect

drain on bottom of humidifier housing to an open drain.

2. Use supplied worm clamp to hold drain tubing in position over

drain fitting outlet.

Unit may leak if drain tubing is misapplied. Do not insert
tubing inside of drain fitting outlet.

3. Make sure line is free of traps due to sagging and has

sufficient pitch to drain.

Fig.

1—Installation

of

HUMCCLBP2018-A--

Bypass-Type Humidifier

A98363

BYPASS UNITS ONLY

VERTICAL

HORIZONTAL

BYPASS UNITS

DRILL (2) HOLES
IN DUCT
FOR #8 SHEETMETAL
SCREWS

"N" COIL

Fig. 2—Preparing Plenum Opening

A97096

TEMPLATE

PLENUM

LEVEL

Fig. 3—Mounting the Humidifier

A98364

FOAM TAPE

NOTCH

SCREWS

2