6 troubleshooting – Crown Audio CE 2000 User Manual

Page 20

Advertising
background image

CE Series Power Amplifiers

page 20

Operation Manual

CONDITION: Power indicator is off.

POSSIBLE REASON

•

The amplifier has lost AC power.

•

The amplifier’s Power switch is off.

•

The amplifier’s power cord is not plugged in at

either end.

•

The amplifier’s circuit breaker has tripped.

Allow the amplifier to cool, remove excessive
loads, and press the reset switch on the front
panel.

CONDITION: No input signal (Signal indi-
cator is not flashing even though audio is applied).

POSSIBLE REASON:

•

Input signal level is very low.

•

Master audio from mixer turned down.

•

Input cable broken or not plugged in.

•

Front-panel Level controls are turned down.

CONDITION: Fault indicator is
flashing.

POSSIBLE REASON:

•

The amplifier has just been turned on and is

still in the 4-second turn-on delay.

•

The heatsinks are too hot.

•

The transformer thermal protection is activated.

•

The amplifier output wires have developed a

short circuit.

•

The amplifier output stage has stopped operat-

ing. Refer the unit to an authorized Crown Ser-
vice Center

The fault status of the amplifier can also be moni-
tored remotely by attaching a signal device to the
Fault jack located on the amplifier back panel. See
Section 4.2.2 for more detail.

CONDITION: Distorted sound.

POSSIBLE REASON:

•

Load is wired incorrectly or Stereo/Mono

mode switch is set incorrectly. Check both.

•

Input signal level is too high. Turn down your

amplifier level controls, or turn down the input
signal, until the clip LED goes out.

Note: If sound is distorted but clip LED is not flash-
ing, check mixer levels and gain staging, mixer clip
lights, and pads built into microphones.

CONDITION: Input signal but no
sound.

POSSIBLE REASON:

•

Speakers not connected. Make sure the Neutrik

NL4 connector is fully seated and locked.

6 Troubleshooting