10

User Manual

8. Time Setting

8-1 Time
Not used.
8-2 Sleep Timer
Set sleep timer.
8-3 Auto Sleep
The monitor turns off when it does not

receive any signal from the remote

control or any button within the time set

up (Off/ 1 Hour/ 2 Hours/ 5 Hours).
(A screen warning is displayed before

the configured automatic shutdown

time).

9. Memory Recall

Reset the screen to the factory preset

display settings.

Lock

1. Keypad Lock

Turn the keypad lock on or off.

2. Remote Control Lock (optional)

Turn the remote control lock on or off.

Self-diagnosis

If there is no image, the Self-Diagnosis screen

will be displayed. The self-diagnosis function

checks if the status of the monitor screen is

No Signal, Out of Range, or None Supported.

The

No Signal screen is displayed when the

D-Sub signal connector is connected but the

status of the monitor is on DPMS mode.

The

Out of Range screen is displayed when

the applied frequency is under or over normal

range.

Normal range (Non-interlaced mode only):
H: 30 to 80 kHz
V: 56 to 77 Hz

Press any key to cancel.
Monitor is turned off when it does not receive

any signal from the remote control or any

button within the time that set up.

Removing the monitor

stand

1. Turn off the monitor and unplug the

power cable.

2. Place a cushion or a soft cloth on the

floor and put the monitor on it with the

front of the monitor facing the floor.

3. Detach the rear cover of the monitor

stand with a screwdriver.

4. Remove the four screws connecting the

stand and monitor body. See figures

below.