Technical service, Warning – Desa Tech CGP11 User Manual

Page 20

Advertising
background image

20

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

POSSIBLE
CAUSE

1. Heater burning vapors

from paint, hair spray,
glues, etc.

2. Low fuel supply
3. Gas leak.

See Warn-

ing statement at
top of page

1. Not enough fresh air is

available

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak.

See Warn-

ing statement at
top of page

2. Control valve defective

1. Foreign matter between

control valve and
burner

2. Gas leak.

See Warn-

ing statement at
top of page

REMEDY

1. Ventilate room. Stop us-

ing odor-causing prod-
ucts while heater is run-
ning

2. Refill supply tank
3. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 10)

1. Open window and/or

door for ventilation

2. Contact local propane

gas company

3. Clean ODS/pilot (see

CLEANING AND
MAINTENANCE, page
17)

1. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 10)

2. Replace control valve

1. Take apart gas tubing

and remove foreign mat-
ter

2. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 10)

OBSERVED
PROBLEM

Heater produces un-
wanted odors

Heater shuts off in use
(ODS operates)

Gas odor even when
control knob is in OFF
position

Gas odor during com-
bustion

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

TECHNICAL

SERVICE

!

WARNING ICON

G 001

WARNING

Advertising