Danger, Caution, Warning – Coleman 5453A User Manual

Page 4: Leak check, English-3

Advertising
background image

English-3

To Set Up

Technical
Characteristics

Input: 7,500 BTU/H per burner
Category: Pressure regulated propane
Fuel: 16.4 oz. disposable propane cylinders
Regulator: 5430

DANGER

• CARBON MONOXIDE HAZARD

• For outdoor use only.
• Never use inside house, camper, tent, vehicle

or other unventilated or enclosed areas. This
stove consumes air (oxygen). Do not use in
unventilated or enclosed areas to avoid
endangering your life.

NOTE: Use Coleman 16.4 oz. disposable propane

cylinders. The LP-gas cylinder(s) used with stoves
must be constructed and marked in accordance
with the specifications for LP-gas cylinders of the
U.S. Department of Transportation or

Transport

Canada, CAN/CSA B339

.

■ Turn FUEL VALVE “off”. (Fig. 1)

CAUTION

• SERVICE SAFETY

• Keep all connections and fittings clean.

Inspect propane cylinder and stove propane
connections for damage before attaching.

• During set up, check all connections and

fittings for leaks using soapy water. Bubbles
indicate a leak. Never use a flame.

WARNING

• Perform leak test outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the outdoor stove until connection

has been leak tested and does not leak.

Leak Check

Fig. 1

Fig. 2

■ Remove plastic cap from top of propane cylin-

der and screw propane cylinder into regulator
hand tight. (Fig. 2)

■ Screw regulator into stove hand tight. (Fig. 3)

Fig. 3

Advertising