6. Boost cycle

If the test result is below 0.1ppm, press and hold “BOOST”

button for 5 seconds until the indicator lights up and the

LED display display “80”. This indicates that the saltwater

system has started copper ion and more chlorine sanitizer

production.

You can press and hold the “BOOST” button for another 5

seconds until the indicator is off, which will cancel the Boost

cycle.

Note: Once the system has started copper ion and more chlorine sanitizer

production, the boost button can’t be re-set until the power switch is off.

The boost operating hours is 8 times the amount of time programmed into the

system, i.e. if your saltwater system operating time is 2 hours, the boost procedure

will run 8 x 2 = 16 hours. After boost procedure has been completed, the system

will automatically switch to the normal working mode.

After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the

pool again.

7. Test pool water regularly:

Once the copper level appears to be balanced, test the pool water every week

to maintain the proper sanitizer level.

It’s very important that the free chlorine is between 0.5-3 ppm and copper

ion concentration is between 0.1~0.2 ppm. When the copper level is below 0.1

ppm, repeat step 6.

NOTE: A High copper ion concentration may cause blonde hair to exhibit a

green hair. To prevent this, wear a swimming cap during swimming, and wash

hair with special shampoo after using the pool.

See “Troubleshooting Guide”.

8. Stand-by/power saving mode:

When the cycle ends, the green “SLEEP” indicator on the

control panel lights up and the LED display flashes “93”.

The system is now in Stand-By mode. After a while, it

shuts down and sets itself in a Power Saving mode. The

system will automatically turn itself back on in 24 hours,

starting its daily cycle of chlorine production.

The “SLEEP” indicator stays on, while the system is in the

Power Saving mode. The LED display however, goes blank

after 1 hour. Press any button ( or ) to view the last LED

code.

9. Running the pump alone without the Saltwater System:

To run the pump alone without the Saltwater System function,

press and hold both and buttons until you hear a

“beep”, the LED display will show “FP”. The pump is now

operating alone. NOTE: The pump cannot be operated alone

under an automatic timer mode. To stop the pump, manually

turn the switch OFF.

IMPORTANT: To keep the initial automatic operating cycle

setting of the Saltwater System, turn the switch ON, the LED

display will show “FP”, and then press until you hear a “beep”.

The LED display will now show the initial input hours and the Saltwater System

cycle will repeat again.