SAVE THESE INSTRUCTIONS

Page 2

(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013

English

189

PO

S AVE THESE INSTRUCTIONS

English

Page 20

FLOW SENSOR CLEANING

ELECTROLYTIC CELL CLEANING

IMPORTANT

Close plunger valves on your pool or insert black hat-like plugs in strainer opening to

prevent water spillage. Open plunger valves or remove plugs when maintenance is

completed.

WARNING

Always unplug this product from the electrical outlet before removing, cleaning,

servicing or making any adjustment to the product.

1. In a counter-clockwise motion unscrew the collar of the flow sensor (11) and remove it from

the electrolytic cell conduit

. See “Part Reference”.

2. If deposits and debris are seen on the surface of the flow sensor, then use a garden hose to

wash it off.

3. If flushing with water does not remove the deposits, use a plastic brush to clean the surface

and the hinge if necessary. Do not use a metal brush.

4. After the flow sensor has been inspected and cleaned, align the locator notch on the flow

sensor to the connection ridge in the conduit. Now turn the collar in a clockwise motion,

tightening the sensor back into its position. Do not over tighten.

Connection Ridge

Locator Notch

Hinge

The electrolytic cell has a self cleaning function incorporated into the electronic control's

programming. In most cases this self cleaning action will keep the cell working at optimum

efficiency. If the pool water is hard (high mineral content) the cell may require periodic manual

cleaning. To maintain maximum performance, we recommend that you open and visually inspect

the electrolytic cell once every month.

The following steps provide instructions on how to clean your cell.

MAINTENANCE