163

SAVE THESE INSTRUCTIONS

Page 28

(163) MODEL CS15110 SAND FILTER PUMP & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 11/08/2011

English

MM

AA

IINN

TT

EE

NN

AA

NN

CC

EE

MOTOR PRE-FILTER CLEANING AND MAINTENANCE

1. Make sure the filter pump is switched off, then disconnect the power cord from

the electrical outlet.

2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down

until it stops and then turn it clockwise until the plastic protruding notch anchors
in the "0/1" position. Repeat for the second plunger valve. This prevents the
water from flowing out of the pool.

3. Release the pressure first by opening the

sediment release valve (19) located
on the lower side of the pre-filter housing
(see drawing 34).

4. In a counter-clockwise motion unscrew the

leaf trap cover (14), then remove the
basket (16) and leaf trap o-ring (15) from the
pre-filter housing (see drawing 35).

5. Empty and flush the basket using a garden

hose, may use a plastic brush to remove
deposits from the basket. Do not use metal
brush.

6. Clean and rinse the inside of the pre-filter

housing and the leaf trap O-ring with
a garden hose.

7. Reinstall the leaf trap O-ring, basket and leaf

trap cover to the pre-filter housing.

8. Close the sediment release valve (19) back.

1

2

34

35

F

FLLO

OW

W S

SE

EN

NS

SO

OR

R C

CLLE

EA

AN

NIIN

NG

G

19

14

16

15

1.

In a counter-clockwise motion unscrew the collar of the flow sensor (21)
and remove it from the electrolytic cell conduit (22). See “Part Reference”.

2. If deposits and debris are seen on the surface of the flow sensor, then use

a garden hose to wash it off.

3.

If flushing with water does not remove the deposits, use a plastic brush to
clean the surface and the hinge if necessary. Do not use a metal brush.

4. After the flow sensor has been inspected and cleaned, align the locator

notch on the flow sensor to the connection ridge in the conduit. Now turn
the collar in a clockwise motion, tightening the sensor back into its position.
Do not overtighten.