Page 14

mAintenAnce And

serVicing

Procedures not specifically

explained in this manual

must be performed only by a

qualified technician.

tO preVent

seriOus injury

FrOm AccidentAl

OperAtiOn:

turn the power switch of the

tool to its “OFF” position and

unplug the tool from its

electrical outlet before

performing any inspection or

maintenance.
tO preVent seriOus

injury FrOm tOOl

FAilure:

do not use damaged

equipment. if abnormal noise

or vibration occurs, have the

problem corrected before

further use.

cleaning, maintenance, and

lubrication

BeFOre eAch use,

1.

inspect the

general condition of the tool. Check

for loose screws, misalignment or

binding of moving parts, cracked or

broken parts, damaged electrical wir-

ing, and any other condition that may

affect its safe operation.
AFter use,

2.

When using latex paint,

clean the sprayer and components

with clean water. When using oil

based paint, use mineral spirits to

clean the sprayer and components.

Lock the Gun and remove the Spray

a.

Tip assembly.
Submerge the Suction Tube in a

b.

container with the appropriate clean-

ing solution.
Place the waste material container

c.

next to the paint container.
Aim the Spray Gun into the paint

d.

container and pull the trigger.
Turn the Power switch to the “ON”

e.

position and the “PRIME/SPRAY”

knob to “SPRAY”. Purge the paint

into the original container until the

cleaning solution starts coming out.
Move the Spray Gun to the waste

f.

container and continue holding the

Trigger down until the cleaning fluid

coming out is paint-free.
Release the Trigger, turn the

g.

“PRIME/SPRAY” knob to “PRIME”

and pull the trigger once to release

pressure.
Turn the power switch of the unit

h.

“OFF” and lock the Gun.
Remove the Suction Hose and re-

i.

turn tube and clean them.
Wipe the thread of the inlet nut and

j.

remove and clean the inlet filter.
Thread the suction tube back in

k.

place and reconnect the return tube

onto the return tube fitting.
Submerge the suction set in a con-

l.

tainer of NEW cleaning solution.
Turn the “PRIME/SPRAY” knob to

m.

“PRIME” and squeeze the trigger

once into the waste container to

relieve pressure.
Allow the pump to circulate the

n.

cleaning solution through the suction

set for three minutes. If oil based

paints were used, the unit must

Advertising