Check network wiring, Isys, G-series touchpanel interface crestron tps-ga-tpi – Crestron electronic TPS-GA-TPI User Manual

Page 50

Advertising
background image

Isys

®

G-Series Touchpanel Interface

Crestron TPS-GA-TPI

TPS-GA-TPI Troubleshooting (Continued)

TROUBLE

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Interface is not
responding to
Cresnet.

ICMP is disabled.

Enable ICMP by typing ICMP
ON

at the command prompt

in the Toolbox Text Console.

Wrong VT Pro-e or
SIMPL Windows

programs.

Verify correct programs.
Verify proper video set up.

No video
displayed.

Incorrect input
connection.

Verify video input and QM
connections.

IP address not correct
(LAN green and amber
LEDs are off).

Assign correct IP address to
TPS-G-TPI.

TPS-GA-TPI does
not respond to
ping command.

IP mask not correct
(LAN green and amber
LEDs are on).

Assign correct IP mask.

PC and TPS-GA-TPI not
on same subnet.

Ensure that the PC and the
TPS-GA-TPI are on the same
subnet.

Incorrect Touch settings.

Check Touch settings on
INTERFACE MENU.

Mouse or attached
touchpanel does
not work.

Incorrect Calibration.

Use Toolbox function Setup
Mode to perform calibration.

Interface does not
communicate with
RS-232 devices.

Incorrect RS-232
settings.

Match communication
settings of interface to
peripheral device.

Attached interface
display is dark.

Standby timeout has
elapsed.

Touch the screen to
reactivate.

Unexpected
response from the
interface.

Interface is incorrectly
calibrated.

Enter “SETUP MODE” and
recalibrate.

Improper Ethernet
connection.

Verify proper connection at
interface LAN port.

Communications
via the LAN port is
not functioning.

Another device set to
the same IP address.

Obtain new interface static IP
address.

Check Network Wiring

Use the Right Wire

In order to ensure optimum performance over the full range of your installation
topology, Crestron Certified Wire and only Crestron Certified Wire may be used.
Failure to do so may incur additional charges if support is required to identify
performance deficiencies because of using improper wire.

Calculate Power

CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to
do so could cause equipment damage or void the Crestron warranty.

CAUTION: Provide sufficient power to the system. Insufficient power can lead to
unpredictable results or damage to the equipment. Please use the Crestron Power
Calculator to help calculate how much power is needed for the system
(

www.crestron.com/calculators

).

When calculating the length of wire for a particular Cresnet run, the wire gauge and
the Cresnet power usage of each network unit to be connected must be taken into

46