Option specifications, Barcode specifications, Option specifications -6 – Canon DR-X10C User Manual

Page 101: Barcode specifications -6

Advertising
background image

7-6

Chapter 7 Appendix

2.

Option Specifications

This section contains the specifications for the separately sold Barcode Module

(p. 7-4)

and imprinters. Refer to

“Using Patchcode

Sheets (Option)” (p. 3-18)

for the specifications of the patchcodes that can be detected by the patchcode decoder.

Barcode Specifications

The following barcodes can be read by installing the optional
barcode module.

Barcode Types

Note: EAN, UPC-A and UPC-E add-ons supported

Detection Conditions

Code

No. of Digits

Checksum

EAN

8 or 13

Modulus 10, Weight 3

Codabar

3 to 32 (including
Start/Stop characters)

Modulus 16, 7 DR

Code 39

3 to 32 (including
Start/Stop characters)
(Standard ASCII or
Full ASCII)

Modulus 43

ITF

2 to 32 (Even
number. of digits
only)

Modulus 10, Weight 3

Code 128

1 to 32 (Valid data
only)

Modulus 103

UPC-A

13

Modulus 10, Weight 3

UPC-E

8

Modulus 10, Weight 3

Item

Condition

Printed
Side

Front or back (or both, but at reduced speed)

Orientation

Perpendicular (0 degrees) or parallel (90
degrees) to the feeding direction

Reading direction should be specified
beforehand

Note: Speed is slow when both directions are
specified.

Size

Line Width

0.012" to 0.039" (0.3 to 1
mm)
When module width exceeds
0.021" (0.508 mm), Code
128, UPC-A, UPC-E and
EAN detect incorrectly

Code Width

4.134" (105 mm) or less
(including quiet zone)

Bar Height

At least 0.393" (10 mm)

Margins

At least one character at each
end

Slew

Within ±3º

Element
Ratio

2.2 to 3.0

PCS Value

At least 0.60 (with a white point of at least
75% reflectance)

Feeding
Direction

0 degrees

90 degrees