EDS Series Factory Sealed
Manual Motor Starting Switches
and Enclosures

Ordering Information
With Allen-Bradley Bulletin 600 Switches

Maximum HP Ratings

Poles

115–230
Volts AC

115–230
Votts DC

Cat. #

1

1 hp

A B BUL 600 TOX4

2

1 hp

3

/

4

hp

A B BUL 600 TOX5

Poles

Hub
Size in.

Dead end Cat. #

Through feed Cat. #

Single Gang

1

3

/

4

EDS2199

➀

EDSC2199

➀

1

EDS3199

➀

EDSC3199

➀

2

3

/

4

EDS21100

➀

EDSC21100

➀

1

EDS31100

➀

EDSC31100

➀

Two Gang

1

3

/

4

EDS2299

➀

EDSC2299

➀

1

EDS3299

➀

EDSC3299

➀

2

3

/

4

EDS22100

➀

EDSC22100

➀

1

EDS32100

➀

EDSC32100

➀

Heater Table (Allen-Bradley)

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

0.17

P1

2.92

P22

0.21

P2

3.09

P23

0.25

P3

3.32

P24

0.32

P4

3.77

P25

0.39

P5

4.16

P26

0.46

P6

4.51

P27

0.57

P7

4.93

P28

0.71

P8

5.43

P29

0.79

P9

6.03

P30

0.87

P10

6.83

P31

0.98

P11

7.72

P32

1.08

P12

8.24

P33

1.19

P13

8.9

P34

1.30

P14

9.6

P35

1.43

P15

10.8

P36

1.58

P16

12.0

P37

1.75

P17

13.5

P38

1.88

P18

15.2

P39

2.13

P19

2.40

P20

2.58

P21

With General Electric Switches

Maximum HP Ratings

Poles

115–230
Volts AC

115
Votts DC

230
Votts DC

Cat. #

1

1 hp

1 hp

1

/

4

hp

GE CR101 Y

2

1 hp

1 hp

1 hp

GE CR101 H

Poles

Hub Size
in.

Dead end Cat. #

Through feed Cat. #

Single Gang

1

3

/

4

EDS21093

➀

EDSC21093

➀

1

EDS31093

➀

EDSC31093

➀

2

3

/

4

EDS21094

➀

EDSC21094

➀

1

EDS31094

➀

EDSC31094

➀

Two Gang

1

3

/

4

EDS22093

➀

EDSC22093

➀

1

EDS32093

➀

EDSC32093

➀

2

3

/

4

EDS22094

➀

EDSC22094

➀

1

EDS32094

➀

EDSC32094

➀

Heater Table (General Electric)

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

Max. Motor
Full-Load
Amps

Crouse-Hinds
Symbol Number

.48

G2

3.01

G22

.53

G3

3.27

G23

.58

G4

3.56

G24

.65

G5

3.88

G25

.71

G6

4.22

G26

.78

G7

4.60

G27

.86

G8

5.00

G28

.95

G9

5.43

G29

1.04

G10

5.90

G30

1.14

G11

6.41

G31

1.25

G12

6.98

G32

1.37

G13

7.60

G33

1.49

G14

8.25

G34

1.63

G15

8.95

G35

1.78

G16

9.75

G36

1.95

G17

10.6

G37

2.13

G18

11.4

G38

2.32

G19

12.5

G39

2.53

G20

13.6

G40

2.76

G21

14.8

G41

16.0

G42

Cl. I, Div. 1 & 2, Groups B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA 3, 7B*CD, 9EFG

Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations

*Add GB suffix. Seals must be installed within 1

1

/

2

" of each conduit opening for Group B usage.

➀ Includes one interchangeable heater. Select heater from the table
below individual listings and use symbol number as second section
of the Cat. No. Example: EDS2199-P5. Insert symbol 0 (zero) to omit
heater.

These heaters are for motors rated 40°C continuously. For motors
rated 50°C or 55°C, multiply full load motor current by 0.9 and use
this value to select heaters. Symbol 0 (zero) must be used to indicate
heater omitted.