Chicago Electric 45690 User Manual
Page 9

REAR HEX JAM
NUT (#10)
FRONT HEXT JAM
NUT (#10)
OPERATING
LEVER (#5)
CAP SCREW
(#3)
HEX NUT (#20)
LOWER TONG (#47)
UPPER TONG
(#46)
TONG
TIP
(#48)
FIGURE F
To Use The Power Switch:
1.
The Power Switch (part #25) allows electrical current to the Spot Welder to be turned
“ON” and “OFF”.
(See Figure D, and Assy. Diagram.)
2.
Turn the Power Switch (part #25) sideways in either direction to start the electrical
current. Release the Power Switch to stop the electrical current.
To Use The Operating Lever:
1.
Caution: Never touch the Upper and Lower Tongs (parts #46, #47) when
welding a workpiece. Allow the Tong Tips (part #48) and the workpiece to cool
before handling.
(See Figures A, B, E, and Assy. Diagram.)
2.
The Operating Lever (part #5) allows you to open and close the Upper and Lower
Tongs (parts #46, #47).
(See Figures A, F, and Assy. Diagram.)
3.
Close the Operating Lever (part #5) during the welding process to compress the
workpieces between the Tong Tips (part #48). Open the Operating Lever after the
spark appears and each weld is made to release the workpieces.
(See Figures B,
A, F, and Assy. Diagram.)
SKU 45690
PAGE 9