Crown Boiler CWI069 User Manual

Page 39

Advertising
background image

39

38

Main

burners

light?

24 volts

across

B1 &B2?

Ref er to standing pilot or
intermittent ignition
troubleshooting chart
(page 41 or 42).

*Def ective damper

*Def ective L8148E

*Def ective damper
harness

*Loose damper
harness connection

*Obstruction in path
of damper blade

24 volts across

standing pilot gas

valve terminals or

terminals 5&6 on

S8600 module?

24 volts

across spill

sw itch?

*Chimney blockage

*Chimney system not
constructed in accordance
w ith Parts 7 and 10 of
National Fuel Gas Code.

*Dow n draf t

*Inadequate combustion air
supply in boiler room

Y

N

N

Y

Y

24 volts

across

rollout

sw itch?

*Loose electrical
connection in 24
volt w iring
betw een B1 or B2
and gas valve or
module

*Rollout sw itch open.
Replace w ith exact
replacement (see parts
list). Check f or blocked
heat exchanger.

Y

N

N

Y

N

Do burner and

circulator shut

dow n at end of

call f or heat?

END

Pull w ire off of T

terminal on

aquastat. Does

boiler shut dow n?

*T'stat or
zone valve
w iring calling
f or heat

*T'stat w ires
shorted

*Internal boiler
w iring
problem,
consult Crow n
representative

Do burners

shut dow n bef ore

gage temp

exceeds high limit

setting +15F?

*Def ective
L8148A

*Sensing bulb not
bottomed out in
w ell

N

Y

Y

N

N

Y