6-2 battery setting1, Battery setting1 – Panasonic SPX900 User Manual

Page 107

Advertising
background image

107

8

8-6-2

BATTERY SETTING1

The ____ in the Adjustable Range column indicates the preset
mode.

Items/

Data Saved

Adjustable

Range

Remarks

CARD NEAR
END ALARM

ON
OFF

Select whether or not to set the alarm to
beep for P2 CARD NEAR END ALARM.

– C U F –

CARD NEAR
END TIME

3min
2min

Set the remaining time to indicate the P2
CARD NEAR END TIME alarm.

– C U F –

CARD END
ALARM

ON
OFF

Select whether or not to set the alarm to
beep for P2 CARD END ALARM.

– C U F –

CARD REMAIN/
„

5min/

„

3min/

„

Set the length of time for one segment (

„) of

the P2 card’s remaining capacity indicator
bars.
5min: One segment represents 5 minutes.
3min: One segment represents 3 minutes.

– C U F –

Items/

Data Saved

Adjustable

Range

Remarks

PRO14

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.7

:

15.0

When MANUAL is selected in the above
menu, set the NEAR END voltage in 0.1 V
steps.

– C U F –

TRIM14

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.6

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

HYTRON50

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.1

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

HYTRON100

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.2

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

HYTRON120

_

Enable selection under BATTERY SELECT.
_:

Enable selection.

• :

Disable selection.

AUTO
MANUAL

Select auto or manual to set the NEAR END
voltage.
AUTO: Set voltage automatically.
MANUAL: Set voltage manually.

11.0

:

13.1

:

15.0

When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1 V
steps.

– C U F –

Advertising