Models with low-btu standing pilot, Models with intermittent ignition – Louisville Tin and Stove CF504C-H User Manual

Page 2

Advertising
background image

CONTENTS

Contents……………………………………………........... 2
Introduction…………………………………………. 2
Specifications……………………………………….. 2
Safety Rules………………………………………… 3
Helpful Installation Information……………….........…. 3
Connecting the Vent……………………………....…..… 3,4
Combustion and Ventilation Air...................................... 5
Furnace Location………………………………….....…. 6
Rough-In Instructions…………………………..…..…. 6,7
Installation……………………………………….......….. 8
Controls…………………………………………........….. 9
Pilot Flame Adjustment…………………………......….. 9

Lighting & Re-Lighting Instructions……………….. 10,11
Operation………………………………………….....….

12

Terminal Block Wiring Diagram……………….....……

13

Manual Reset…………………………………....……..

13

Maintenance Instructions…………………….………

13

Wiring Diagram……………………………….....…….. 14,15
Side & Rear Discharge Kits……………………...……16,17
Trouble Shooting Chart…………………………..….. 18,19
Repair Parts (break down)………………………..….. 20-24
Repair Parts List…………………………………....…. 21-25
Warranty………………………………………….....….

27

INSTALLER MUST LEAVE THESE INSTRUCTIONS WITH THE CONSUMER, HAVE THEM
COMPLETE, AND RETURN THE WARRANTY CARD.

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED WALL FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN
EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE
INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE
INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE
GAS SUPPLIER, OR THE MANUFACTURER.

COUNTERFLOW WALL FURNACE SPECIFICATIONS

Your counterflow wall furnace is packed in a single carton that also includes thermostat, thermostat wire, and insulated staples.
The thermostat, wire, and staples are packed in the burner compartment and are accessible by removing the burner access door.
While the burner access door is open, check the rating plate to verify that the model number is correct and that the wall furnace
is equipped for the type gas you intend to use.

Vent

Approx.

Model

Type

Type

BTU/HR.

Size

Gas

Blower

Shipping

Number Control Gas

Input

(Oval)

Inlet

Finished Dimensions

Speed Amps CFM

Weight

MODELS WITH LOW-BTU STANDING PILOT

CF353C-H 24 Volt Nat.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H 1

1.95

320

95 Lbs.

CF354C-H 24 Volt L.P.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H 1

1.95

320

95 Lbs.

CF503C-H 24 Volt Nat.

50,000

4”

½” 14-5/16”Wx10¼”Dx81-5/16”H 2

2.25

440

104 Lbs.

CF504C-H 24 Volt L.P.

50,000

4”

½” 14-5/16”Wx10¼”Dx81-5/16”H 2

2.25

440

104 Lbs.

CF653C-H 24 Volt Nat.

65,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H 2

2.25

440

107 Lbs.

CF654C-H 24 Volt L.P.

65,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H 2

2.25

440

107 lbs.

MODELS WITH INTERMITTENT IGNITION

CF357C-H 24 Volt Nat.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8” H 1

2.2

320

95 Lbs.

CF358C-H 24 Volt L.P.

35,000

4”

½” 14-5/16”Wx10¼”Dx78-5/8”H 1

2.25

320

95 Lbs.

CF557C-H 24 Volt Nat.

55,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H 2

2.5

440

107 Lbs.

CF558C-H 24 Volt L.P.

55,000

4”

½” 14-5/16”Wx10¼”Dx87-5/16”H 2

2.55

440

107 Lbs.

Page 2

Advertising