9.

Push in gas control knob all the way and hold. Immedi-
ately light the pilot by repeatedly depressing the piezo spark
ignitor until a flame appears. Continue to hold for about
one (1) minute after the pilot is lit. Release gas control knob
and it will pop back. Pilot should remain lit. If it goes out,
repeat steps 5 through 8, page 23.
• If gas control knob does not pop up when released, stop and

immediately call your service technician or gas supplier.

• If the pilot will not stay lit after several tries, turn the gas

control knob to “OFF” and call your service technician
or gas supplier.

10. Turn gas control knob counterclockwise

to “ON”.

11. Turn on all electric power to the burner system.

12. Turn the ON/OFF switch to ON position.

13. This valve is equipped with a HI/LO feature. Set burner

system input as desired.

14. Close lower panel.

OPERATING STOVE WITH
BURNER SYSTEM

Continued

1.

Open lower panel.

2a. Turn ON/OFF switch to “OFF”.

2b.

If Using Optional Hand-Held Remote:

Set selector switch

in the OFF position to prevent draining battery.

3.

Turn off all electrical power to the appliance if service is to
be performed.

4.

Push in gas control knob slightly and turn clockwise
to “OFF”.

5.

Close lower panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one
of the following:

1.

Turn gas control knob clockwise

to the PILOT

position.

2.

Set selector switch in the OFF position.

1.

Remove glass door (see Removing/Replacing Glass Door,
pages 21 and 22).

2.

Follow steps 1 through 8 under Lighting Instructions,
page 23.

3.

Depress gas control knob and light pilot with match.

4.

Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Now
follow steps 10 through 14, column 1.

5.

Replace glass door (see Removing/Replacing Glass Door,
pages 21 and 22).

TO TURN OFF GAS

TO APPLIANCE

MANUAL LIGHTING

PROCEDURE

Figure 55 - Control Valve

1.

After lighting, let pilot flame burn for about one minute.
Turn gas control knob on the control valve to ON position.
Turn variable control knob anywhere between HI and LO.
Slide the selector switch to the REMOTE position.

Note:

The burners may light if hand-held remote ON button was
on when selector switch was last turned off. You can now
turn the burners on and off with either optional hand-held
remote control unit.

IMPORTANT:

Do not leave the selector switch in the RE-

MOTE position when the pilot is not lit. This will drain the
battery.

IMPORTANT:

Be sure to press the ON/OFF buttons on the

hand-held remote control unit for up to 3 seconds to assure
proper operation.

Note:

All remote control accessories must be purchased sepa-

rately (see Accessories, page 36). Follow instructions included
with the remote control.

Thermostat Control Operation

(Optional CGHRCTA Only) The thermostat control setting on
the remote control unit can be set to any comfort level between
HI and LO. The burners will turn on and off automatically to
maintain the comfort level you select. The ideal comfort setting
will vary by household depending upon the amount of space to
be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the
hand-held remote control unit. See

Lighting Instruc-

tions, pages 23 and 24.

OPTIONAL REMOTE

OPERATION

OPERATING STOVE WITH BURNER SYSTEM

LIghting Instructions (Cont.)
To Turn Gas Off To Appliance
Manual Lighting Procedure
Optional Remote Operation

P

IL

OT

O

F

F

PIL

OT

O

N

TPTH TP TH

HI

LO

IN

OUT

Gas Control Knob

Variable
Control Knob

Piezo
Ignitor