Service and maintenance, Deactivation, Battery pack – Kannad Marine PRO PLB User Manual
Page 13
 
12
Service and Maintenance
After use (not activated) 
Clean the outer case with fresh water, wipe dry and examine for any damage. Store in 
a cool dry place. 
 
Inadvertent antenna deployment 
If the red anti-tamper seal is removed, the antenna will automatically deploy. Re-
winding the antenna and fitting a new anti-tamper seal can only be done by a Orolia 
Ltd authorized service station. For safe transportation, wrap the antenna around the 
body of the PLB and fix in place with adhesive tape. Do not close or fold the flip-up lid 
over the top of the deployed antenna as this may damage the antenna. 
NOTE: Antenna re-winding will incur a service charge. 
CAUTION: Never attempt to re coil the antenna
 
Service 
Battery packs, flip cover and lanyard are user replaceable. The main body of the PLB 
has no user-serviceable parts. A list of Kannad Marine dealers and Service Agents is 
located on the Kannad Marine web site, 
Deactivation
The PLB may be completely deactivated by removing the battery pack. 
Important: When the battery pack is removed the PLB is no longer fully 
environmentally sealed and should not be subjected to water. 
Battery Pack
The battery pack is easily user replaceable, order code 85-763-020A 
 
Once the battery expiry date has 
been reached it must be replaced. 
Only fit an original Kannad branded 
-20 °C Class 2 Battery Pack kit. 
Battery packs provide a minimum of 48 hours 
continuous operation at a minimum temperature of 
-20 °C (-4 °F) and maximum of +55 °C (+131 °F). 
The battery may safely be stored in temperatures up 
to +70 °C (+158 °F). 
CAUTION: Never attempt to recharge the Battery
Pack