KERN & SOHN IFS 300K-3 User Manual

Page 17

Advertising
background image

KFS-T-BA_IA-e-1213

17

Call menu item linearization

, see chap. 6.5

Confirm menu setting

with

.

Ensure that there are no objects on the weighing plate.

“LoAd 1” will be displayed after standstill control has been carried out. Put the

first adjustment weight approx. 1/4 Max (see table 1) carefully in the centre of the

weighing pan.

“LoAd 2” will be displayed after standstill control has been carried out.

Put the second adjustment weight approx. 2/4 max (see table 1) carefully in the

centre of the weighing pan. “LoAd 3” will be displayed after standstill control has

been carried out.

Put the third adjustment weight approx. 3/4 max (see table 1) carefully in the

centre of the weighing pan. “LoAd 4” will be displayed after standstill control has

been carried out.

Put the forth adjustment weight approx. 4/4 max (see table 1) carefully in the

centre of the weighing pan.

After successful standstill control the balance carries out a selftest, then it

automatically returns to weighing mode.

An adjusting error or incorrect adjusting weight will be indicated by the error

message; repeat adjustment procedure.

You can cancel adjustment by pressing any key with the exception of

and

.

Advertising
This manual is related to the following products: