Installation Instructions

Everhot Horizontal Discharge Vent System

Identify the vent location

Figure 32

Steps:
- Place horizontal discharge adapter on water heater
- Mark position on wall
- Or use template provided with water heater
- Cut hole, covering the top of the water heater to prevent debris from entering


Measure dimension to fit

Figure

34

Figure 33

NOTICE

Note: if the vent system is shorter than 5 ft. (1,52 m) and no condensate collector is installed, be sure
to install the wall terminal with a 1° angle to the outside of the building.