SECTION 1.

General Information

In the Commonwealth of Massachusetts, this

appliance must be installed by a licensed plumber or

gas fitter.

WARNING

The Pennant pool heater

must be installed in

accordance with the procedures detailed in this

manual, or the Laars Heating Systems warranty

may be voided. The installation must conform to

the requirements of the local jurisdiction having

authority, and, in the United States, to the latest

edition of the National Fuel Gas Code, ANSI

Z223.1/NFPA54. In Canada, the installation must

conform to the latest edition of CAN/CGA-B149.1,

Natural Gas Installation Code or CAN/CGA-B149.2,

Propane Gas Installation Code, and/or local codes.

Where required by the authority having jurisdiction,

the installation of Pennant appliances must

conform to the Standard for Controls and Safety

Devices for Automatically Fired Boilers, ANSI/

ASME CSD-1. Any modifications to the boiler, its

gas controls, or wiring may void the warranty. If field

conditions require modifications, consult the factory

representative before initiating such modifications.

1.1 Introduction

This manual provides information necessary for

the installation, operation, and maintenance of Laars

Heating Systems Pennant copper tube pool heaters.

Read it carefully before installation.

All application and installation procedures

should be reviewed completely before proceeding with

the installation. Consult the Laars Heating Systems

factory, or local factory representative, with any issues

or questions regarding this equipment. Experience

has shown that most operating issues are caused by

improper installation.

The Pennant appliance is protected against over

pressurization. A pressure relief valve is fitted to all

appliances. It is installed on the outlet header, at the

water outlet of the appliance.

IMPORTANT: The inlet gas pressure to the appliance

must not exceed 13" W.C. (3.2kPa).

All installations must be made in accordance

with the 1). American National Standard Z223.1/

NFPA54-Latest Edition “National Fuel Gas Code”

or 2). CAN/CGA 1-B149 “Installation Codes for Gas

Burning Appliances and Equipment” and with the

requirement of the local utility or other authorities

having jurisdiction. Such applicable requirements take

precedence over the general instructions contained

herein.

All electrical wiring is to be done in accordance

with the local codes, or in the absence of local

codes, with: 1). The National Electrical Code ANSI/

NFPA No. 70-latest Edition, or 2). CSA STD. C22.1

“Canadian Electrical Code - Part 1”. This appliance

must be electrically grounded in accordance with these

codes.

1.2 Model Identification

Consult the rating plate on the unit. The

following information describes the model number

structure.

Model Character Designation

1-3 Model Series Designation

P N C = Pennant

4 Usage

P = Pool Heater

5-8 Size

0 5 0 0 = 500,000 BTU/h input

0 7 5 0 = 750,000 BTU/h input

1 0 0 0 = 999,000 BTU/h input

1 2 5 0 = 1,250,000 BTU/h input

1 5 0 0 = 1,500,000 BTU/h input

1 7 5 0 = 1,750,000 BTU/h input

2 0 0 0 = 1,999,000 BTU/h input

9 Fuel

N = Natural Gas

P = Liquid Propane

10 Altitude

A = 0-10,000 feet

11 Location

C = Indoor and Outdoor

12 Firing Mode

C = On-off

13 Revision

2 = Second version

1 2 3

4 5 6 7 8 9

10

11

12

13

14

15

16

P N C P

A

C

C

2

SERIES

P

N

C

USAGE

P

SIZE

0 5 0 0

0 7 5 0

1 0 0 0

1 2 5 0

1 5 0 0

1 7 5 0

2 0 0 0

FUEL

N
P

ALTITUDE

A

FIRING

MODE

C (ON/OFF)

LOCATION

C

REVISION

2

HEAT

EXCHANGER

B
P

OPTIONS

CODE

X

J

PUMP

OPTIONS

N
B

Advertising