LABEC PLRGD-1400PT User Manual

Page 2

Advertising
background image

Introduction 
Congratulations on the choice of another quality product. Labec products are manufactured, tested

 

 

 

   

 

 

 

 

 

 

 

 

and calibrated to meet published standard specifications under our strict quality assurance

 

 

 

 

 

 

 

 

 

 

 

 

guidelines. 
 
This Instruction Manual is for the guidance of operators of Labec Pass Through Fridges and should

 

 

   

 

 

   

   

 

 

 

 

 

 

be read before the fridge is connected to the electricity supply. 
 
It is hoped that this manual will supply all the information that the customer should require for

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

satisfactory operation of this product. If, however, there are any questions that remain unanswered

 

   

 

   

 

 

 

 

 

 

 

 

then the customer should contact our Service Department. 
 
Unpacking 
Remove all packing and protective wrapping from both interior and exterior of the fridge. Check the

   

 

 

 

 

 

 

 

 

   

 

 

 

 

fridge for any possible transit damage. Ensure all ordered accessories are present. If any physical

 

 

 

 

 

 

   

 

 

 

   

 

 

damage or shortages are evident, do not discard the packaging material until the fridge is inspected

   

 

 

   

 

 

 

 

 

 

 

   

 

by the distributor, agent or manufacturer. 
NOTE: All claims for shortage or damage must be made within fourteen days (14) from delivery. 
Subject to our standard published conditions of sale, we have reasonable grounds to believe that we

   

 

 

 

   

 

 

 

 

   

 

 

 

have ensured, so far as is reasonably practical, that the products listed in our catalogue and

 

 

 

 

   

 

 

 

 

 

   

 

 

 

brochures have been designed and constructed so as to be safe and without risk to health when

 

 

 

 

 

 

 

   

 

 

 

 

   

 

 

properly installed and used in their environment by appropriate and trained personnel, and where

 

 

 

   

 

 

 

 

 

 

 

 

 

applicable, in accordance with our published instructions. 
 
Electrical Installation 
This equipment must be tagged and tested according to AS/NZS3760:2010 prior to use and

 

 

 

 

 

 

 

   

 

   

 

 

thereafter on a regular basis dependent upon the environment.  
 
It is preferable to locate the fridge as close to a power point and recommended that double adaptors

   

   

 

 

   

     

 

 

 

 

 

 

 

are not used. Check the total wattage if connecting to multi­point outlets. Check the rating plate for

 

 

 

 

 

 

   

   

 

 

 

 

 

 

 

power requirements. Installation is to be carried out by a qualified electrician in accordance with the

 

 

     

 

 

     

 

   

 

 

 

power requirements of the product specifications. The unit must be EARTHED.  
 
DANGER: THIS FRIDGE MUST NOT BE CONNECTED TO DIRECT CURRENT SUPPLY 
 
 
Doors 
The doors are interlocked with solenoid pins which run on 12­24V DC power. Ensure doors are  
not slammed or pulled too hard when locked as the locking pin may be bent or damaged. 
When the doors are opened the opposite doors will both be locked until all doors are closed. 
 
Alarm Output  
The fridge has a safety alarm controller output fitted. When the temperature drops below 2°c or

 

 

   

 

 

 

 

 

 

 

 

 

 

   

above 8°c the controller will flash HI or LO and will buzz. The AUX alarm output connection can be

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

   

connected to an external device such as a phone dialler or similar or building maintenance system

   

 

 

 

     

 

   

   

 

 

 

to indicate temperature fluctuations. Do not set the alarm hysterisis too close to the set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature or the alarm will activate too often. To acknowledge the alarm press the Reset button.  
 
Operation 

1. Connect the chamber to an alternating current supply of voltage as specified on the rating

 

 

   

 

 

 

   

 

 

 

 

 

 

plate mounted on the side or rear of the chamber. The main temperature controller will turn

 

 

 

 

   

   

 

 

 

 

 

 

 

 

on automatically.  

2. The temperature controller will switch the fridge on and control temperature.   
3. Set the alarm values if required. (default 2ºC deviation for 30 minutes.) 

 

1        Laboratory Equipment Pty Ltd – Pass Through Fridges Instruction Manual 

Advertising