Leapers 3X Magnifier with Flip-to-side QD Mount, W/E Adjustable (SCP-MF3WEQS) User Manual

Optics, Utg new gen 3x magnifier, Leapers, inc

Advertising
background image

UTG NEW GEN 3X magnifier

B. Major Features:

Rock Solid Robust Construction with High Quality

Precision Machined Parts

Precision machined to exact tolerances from

aircraft-grade aluminum alloy for maximum

strength.

Completely sealed and nitrogen filled to eliminate

risk of water ingress and fogging.

Multi Layer Lens Coating for Optimum Light

Transmission

Unique high tech lens coating applications ensure

much superior light transmission and optimize

optical performance.

Multi layer coatings allow for maximum utilization of

all ambient light to optimize resolution and clarity.

3X Magnification and Optic Enhancer for Most Dot

Sights

Ideal profiles for low profile applications that are

close to the bore or medium profile applications for

co-witnessing with iron sights.

Built-in corrective lens system to turn a glaring dot

1 of 8

to the perfect dot when used with a dot sight.

Magnified view through a sharp dot sight provides

an instant improvement on accuracy without any

compromises.

Versatile and Dependable Quick-detach Mounts for a

Wide Variety of Applications (SCP-MF3WQ)

Low profile quick detachable mount with adjustable

positions for optimal eye relief.

A smart riser raises the center height with adjustable

positions for further eye relief adjustment.

Innovative and Solid Flip-to-Side Design for Tactical

Applictions (SCP-MF3WQS, SCP-MF3WEQS)

At vertical position, medium profile to perfectly

co-witness with dot sights and AR iron sights,

providing 3X magnification for accurate aiming.

At flip-over position, clear the view for quick aiming

with dot sight only.

Easy one-hand switch

between two positions,

and solid locking in each

position with no wobbling

under recoil.

C. Mounting the Magnifier:

CAUTION: Always ensure your

rifle is UNLOADED, UNCOCKED and, where applicable,

the safety catch is applied before fitting the scope. Practice

safe handling procedures at all times.

1.

Follow proper installation procedures to install your dot

sight on the rifle.

2.

For SCP-MF3WQ and SCP-MF3WEQS, the magnifier

comes with a low profile QD mount and a versatile riser.

Use the mount only or both mount and riser to match

your dot sight center height.

3.

Hold the magnifier behind the dot sight over the rifle at

your natural shooting position. Locate a proper position

for the magnifier so you can achieve a full field of view.

The low profile QD mount works with or without the riser

to offer adjustable positions for optimal eye relief shown

in

Fig 1. It may require adjustment of the dot sight

position.

Dioptric Adjustment

Dioptric Adjustment

Medium Profile Configuration with Riser & Mounting Deck

Low Profile Configuration with Mounting Deck Only

QD Lever Lock

(Patent: 8397421)

QD Lever Lock

(Patent: 8397421)

Objective Lens

4.

For SCP-MF3WQS/SCP-MF3WEQS, go to Step 5.

For SCP-MF3WQ, based on your selection in Step 2,

attach the mount/riser as follows:

For QD Mount Only:

The mount comes with

3 locking holes allowing

space adjustment to

achieve optimal eye

relief. The mount can

be used bi-directionally

per your preference.

Locate two set screws

and install a spring washer onto each screw. Based on

your eye relief preference in Step 3, select two holes on

the QD mount, fit the mount against the mating base on

the magnifer, and align the mount holes with the magnifer

holes. Install and fasten the set screws to fully secure the

mount as shown in

Fig 2.

For QD Mount with Riser:

This configuration offers many different options from the

bi-directional mounting feature for both the QD mount

and the riser. The riser can be installed in either direction

depending on your preference. The same for the QD

mount. (NOTE: Figures included only show one example

direction.) Locate four set screws and install a spring

washer onto each screw.
I. Install Riser: Align

the riser to the mating

base on the magnifier

based on the direction

suitable for your

application. Install and

fasten two set screws

to fully secure the riser as shown in

Fig 3.

II. Install QD Mount: Based on your eye relief

preference in Step 3, select two holes on the QD

mount and align them to the mating holes on the

extruded part of the riser. Install and fasten the

remaining two set screws to fully secure the mount as

shown in

Fig 3.

w w w . l e a p e r s . c o m

Riser

Mounting

Deck

3 of 8

5 of 8

8 of 8

MODEL NO.: SCP-MF3WQS

MODEL NO.: SCP-MF3WEQS

5.

Align and install the magnifier onto the Picatinny rail with

the position selected in Step 3. Follow instructions below

to adjust for optimal tension

for quick detach, locking and

unlocking.
a. Turn the Cam Lever toward its

unlocked position as shown in

Fig 4. Place the QD mount on

the Picatinny rail at the desired

position. Make sure to seat the

cross bolt into a selected slot.

b. Turn the Cam Lever toward the locking position to begin

locking the QD mount on the rail, but do not complete the

locking motion, leaving some travel distance to allow for

adjustment.

c. Use the included Allen wrench to adjust the hex screw at

the side of the cam for proper tension and fit against the

rail. Adjust clockwise to increase the tension and tighten

the clamping width. Adjust counter-clockwise to decrease

the tension and increase the clamping width.

d. The optimal tension is achieved when the side plate first

makes contact with the Picatinny rail while the Cam Lever

still has enough travel left for you to securely snap into its

locking position. Once you achieve the optimal tension,

push the Cam Lever all the way for a positive lock onto

the rail. You may repeat Step c and d if needed to find

the best clamping tension and locking position for your

mount.

e. Now your QD Cam Lever is set for quick detach

operations. You may regularly inspect and adjust the

tension for best fit.

D.

Switch Between Vertical/Flip-over Positions (for SCP-

MF3WQS/SCP-MF3WEQS):
I. Pull the magnifier back towards you allowing the pins

inside the hinge component to be unlocked as shown in

Fig 5.

II. Rotate the magnifier clockwise till the hinge component

is locked, so that your view is not obstructed as showing

in

Fig 6.

E. Adjusting Focus / Diopter Setting:

NOTE: Different individuals will have different eye focus

which will result in different diopter setting. A person will

use different diopter settings with or without eye glasses.

The repeating process below may cause eye strain and

contribute to parallax error. It will help if you can briefly look

away from the eye piece and then look back through it.

1.

Aiming your dot sight/magnifier at a distant target.

2.

Slightly rotate the focus ring until you have the sharpest

image as shown in

Fig 7.

F. Care and Maintenance:

1.

Take care not to drop or

knock the magnifying scope once it is zeroed.

2.

Maintain the metal surface of the magnifying scope by

removing any dirt or sand with a soft brush so as to avoid

scratching the finish.

3.

Wipe the lens with a clean flannel cloth to keep it clean

and dry. In order to avoid scratching the glass, ensure

both the lens and cloth are clean. Do not use finger or

finger nail to touch/clean lenses.

4.

Store the magnifying scope in a cool dry place when not

in use. Be careful to avoid contact with acid, alkaline or

corrosive chemicals.

6 of 8

7 of 8

Fig 2.

Fig 3.

Fig 1.

Fig 4.

MUO006011104

UTG

OPTICS

Leapers, Inc.

Proudly Presents

magnIfIerS

SCOPeS

ToTal solUTIoN To YoUr NeeDs

-COMMITMENT TO BEST QUALITY, BEST VALUE AND BEST SERVICE-

Tel:(734)542-1500

Fax:(734)542-7095

Email:[email protected]

www.LEAPERS.com

32700 Capitol Street, Livonia, MI 48150, U.S.A.

2 of 8

Medium Profile Configuration with Flip-to-Side QD Mounting Deck

Medium Profile Configuration with Flip-to-Side QD Mounting Deck

and Windage/Elevation Adjustment

Dioptric Adjustment

QD Lever Lock

(Patent: 8397421)

QD Lever Lock

(Patent: 8397421)

Dioptric

Adjustment

4 of 8

Fig 5.

Fig 6.

5.

Do not attempt to lubricate any part of the magnifying

scope.

6.

Do not disassemble the magnifying scope. Do not loosen

or remove screws or parts. Any such or similar actions will

void the warranty.

CAUTION: Viewing the sun can cause serious eye injury.

Never look directly into the sun with this or any scope.

G. Lifetime Manufacturer’s Warranty

Warranty against material or workmanship defects applies based

on the following conditions -

Magnifier scope was a first-hand purchase. Evidence

of purchase is required for warranty service. Warranty

is not transferrable.

Magnifier scope was not disassembled, parts/ screws

not removed or loosened, and the scope was not

tampered with in any way. Any evidence of such

interference will void the warranty.

Magnifier scope has not been abused, maliciously

damaged or treated in a manner not in keeping with

the purpose it was designed for.

For Warranty service, please contact the scope distributor

and provide a written problem description to obtain a Return

Authorization Number before returning the product for repair or

replacement.

UTG FLIP-TO-SIDE 3X MAGNIFIER

UTG FLIP-TO-SIDE 3X W/E MAGNIFIER

MODEL NO.: SCP-MF3WQ

Objective Lens

Objective Lens

Elevation

Windage

Objective Lens

Flip-to-Side QD

Mounting Deck

(Patent D672,839)

Flip-to-Side QD

Mounting Deck

(Patent D672,839)

A. Specifications

Magnification

3X

Objective Diameter

25mm

Field of View

Exit Pupil Diameter

8.7mm

Eye Relief

51mm

Dioptric Adjustment

+/- 1 D

Tube Length

102mm

Weight

SCP-MF3WQ : 260g

SCP-MF3WQS : 280g

SCP-MF3WQS : 335g

Lens Coating

Broadband Multi-layer

Compatible Rail

Picatinny/Weaver

Fig 7.

DOT SIgHTS

42mm

Coil Erector Return Spring

System for Guaranteed Zero

42mm

30mm

40mm

Advertising