Level-Up® Motorhome Leveling Troubleshooting Guide

Troubleshooting
Error Mode

A. If an error occurs before or during operation, the error will be displayed in the LCD and an alarm

will sound. To reset all error or service displays, push ENTER.

B. All normal functions will be disabled when the system is in Error Mode.

LCD Display

What is Happening?

What should be done?

****ERROR****

Excess Angle

Coach not parked on level ground.
Zero point incorrectly calibrated.

Move coach to level ground prior to

starting auto level sequence.
Recalibrate Zero Point.

****ERROR**** External Sensor

Rear sensor shorted out or

disconnected.

Check wire connection or replace

sensor.

Out of Stroke

Jack has insufficient length to

complete the leveling procedure.

Check the disposition of the jack.

Low Voltage

Battery voltage dropped below 9.5

VDC during operation.

Turn engine on, check battery

voltage under load.

Function Aborted

A button was pressed on touchpad

during Auto Level operation.

Hit enter to acknowledge. Restart

procedure.

Unable to Finish Leveling

Excessive movement inside coach

during auto level sequence.

Discontinue movement inside coach

during auto level sequence.

Engage Park Brake

Parking brake not set prior to

starting auto level sequence.

Set parking brake prior to starting

auto level sequence.

Comm Error

Check Wiring

NOTE: Screen will not back light.

Wiring connections loose or faulty

between touchpad and controller.

Check connections, replace

communication harness if necessary.

****ERROR****

Retract Timeout

Return Levelers for Service

Parking Brake not engaged.
Engine is not running prior to

starting auto retract sequence.
Leaking hose or fitting.

Press Enter and Retract. Engage

parking brake.
Press Enter and Retract at the same

time to clear error. Turn engine on

and restart auto retract sequence.
Check for leaks, repair if necessary.

Press enter and retract to clear error.

Excessive Angle

Occurs only in manual mode when

the angle of the unit is too severe.

Use the manual functions to return

coach to a more level condition.

LEVEL-UP

®

MOTORHOME LEVELING

TROUBLESHOOTING GUIDE