Lippert Components In Wall Slide-Out System Winnebago Industries User Manual

Page 4

Advertising
background image

Checking Fuses

The Schwintek In-Wall™ Slide requires a minimum of 30 amp fuse. Check the 12 volt fuse box for

blown fuses, and replace any if necessary. Consult the rv manufacturers documentation for the

location of the 12 volt fuse box, and the location of the Room Slide Controller’s fuse. If the fuse blows

immediately upon replacement, there is a problem with the wiring to the In-Wall™ Slide control box.

Have qualified service personnel check and repair.

Obstructions

Check outside the rv for possible obstructions: tree, post, car, etc… Check inside the rv for any

obstructions: luggage, furniture, open cabinets, etc… Also check for smaller objects that may be

wedged under the floor or in the sides of unit. Remove obstructions before proceeding.

Error Codes

Consult rv manufacturer’s documentation for the location of the In-Wall™ Slide Controller. See page 1

for a description of the error codes, and possible problems.

Low Voltage

The Schwintek In-Wall™ Slide Controller is capable of operating the room with as little as 8 volts.

But at these lower voltages the amperage requirement is greater. Check voltage at the controller. If

voltage is lower than 11 volts, it is recommended that the battery be placed on a charger until it is

fully charged. It may be possible to ’jump’ the rv’s battery temporarily to extend or retract the room.

Consult the rv manufacturer’s owners manual on the procedure for ‘jumping’ or charging the battery.

**********Never ‘jump’ or charge the battery from the power connections on the In-Wall™

Controller. Always do this at the battery.*****************

Only 1 side moving
The Schwintek In-Wall™ Room Slide has a separate moto

r

to operate each side of the room. Does

only 1 side of the room move a short distance (2 to 4 inches) and stop.

Will non moving side move with help?

If only 1 side of the room is moving, then with someone’s assistance press the switch to extend or

retract the room while pushing the non moving side in the appropriate direction. On larger rooms it

may be necessary to have 2 or more people pushing the room.

Non moving side moved manually

Try to push the non moving side in and out. If a motor shaft has broken then it will be possible to

move that side of the room several inches by hand. Larger rooms may require several people to push.

Debris in the rack

Check all 4 gear racks on the side of the room for debris.

Do status led’s light

Consult the rv manufacturers documentation for the location of the Room Slide Controller. When the

room slide direction switch is actuated, do the status led’s light up. Check this in both the extend and

retract modes.

IF YOU HAVE ANY PROBLEMS OR QUESTIONS; CONSULT

YOUR LOCAL AUTHORIZED DEALER OR CONTACT LIPPERT

PHONE: (866) 524-7821 - E-MAIL: [email protected]