Longshine LCS-FS6108-B User Manual

Page 5

Advertising
background image

4

Stations Connection


Connect each station to the switch by twisted-pair
cable. Plug one RJ-45 connector into a RJ-45 port
of the switch, and plug the other RJ-45 connector
into the station’s network adapter. Power on the
switch and then system is ready.
For cable selection, refer to the following table.

The switch supports port-based QoS as the
following table:

Model

High-priority
ports

Low-priority
ports

5-Port Model: Port 1, 2

Port 3, 4 and 5

8-Port Model: Port 1, 2 and 3 Port 3, 4, 5, 6, 7

and 8


The bandwidth ratio of high priority port to low
priority port is 16:1.

Switches Connection


In making a switch interconnection, you could use
any port to connect another switch with straight or
crossover cable. As all the ports support auto MDI
/ MDI-X function, using a straight cable to make a
switch-to-switch connection is allowed.

For cable selection, refer to the following table:

Network Speed Cable Type

Max. Length

10Mbps

Cat. 3, 4, 5
UTP/STP

100 meters

100Mbps

Cat. 5 UTP/STP

100 meters