© Copyright 2005-2007 TERIDIAN Semiconductor Corporation

Name

Purpose

Function or LSB Value

CLI

Format

L in
bits

XDATA

IThrshldA Starting

current,

element A

SQSUM

I

LSB

0

2

16

=

0 in this position disables creep
logic for both element A and B.

)0 unsigned

32 0x0000

Config Configure

meter

operation on the fly.

bit 0:** reserved
0: VA = Vrms * Irms;

1:

2

2

VARh

Wh

VA

+

=

bit1:* 1 = Clears accumulators
bit2:*1 = Calibration mode
bit3:** reserved: 1 = enable
tamper detection

)1 N/A

8 0x0004

VPThrshld

error if exceeded.*

SQSUM

V

LSB

0

2

16

=

)2 unsigned

32 0x0005

IPThrshld

error if exceeded.*

SQSUM

I

LSB

0

2

16

=

)3 unsigned

32 0x0009

Y_Cal_Deg0 RTC

adjust

100ppb

)4 signed 16 0x000D

Y_Cal_Deg1

RTC adjust, linear by
temp.*

10ppb*ΔT, in 0.1?C

)5

signed

16

0x000F

Y_Cal_Deg2 RTC

adjust,

squared

by temp.*

1ppb*ΔT

2

, in 0.1?C

)6

signed

16

0x0011

PulseWSource
PulseVSource

Wh Pulse source,
VARh pulse source
selection*

See table for PulseWSource and
PulseVSource

)7
)8

unsigned 8

0x0013
0x0014

Vmax Scaling

Maximum

Voltage for PCB,
equivalent to 176mV
at the VA/VB pins

0.1V )9

unsigned

16

0x0015

ImaxA Scaling

maximum

current for PCB,
element A, equi-
valent to 176mV at
the IA pin

0.1A )A

unsigned

16

0x0017

ppmc1

ADC linear adjust
with temperature

PPM per degree centigrade

)B

signed

16

0x0019

ppmc2

ADC quadratic adjust
with temperature

PPM per degree centigrade
squared

)C signed 16 0x001B

Pulse 3 source

Source for software
pulse output 3**

See table for PulseWSource and
PulseVSource

)D unsigned

8 0x001D

Pulse 4 source Source for software

pulse output 4**

See table for PulseWSource and
PulseVSource

)E unsigned

8 0x001E

Scal

Duration for auto-
calibration** in
seconds

Count of accumulation intervals to
be used for auto-calibration.

)F unsigned

16 0x001F

Vcal

Voltage value to be
used for auto-
calibration**

Nominal RMS voltage applied to
all elements during auto-
calibration (LSB = 0.1V).

)10 unsigned 16 0x0021