4 on-hook procedures, 1 cid mode, On-hook procedures – Maxim Integrated 73M1822/73M1922 Implementers Guide User Manual
Page 13: Cid mode

UG_1x22_052
73M1822/73M1922 Implementer’s Guide
Rev. 1.0
13
4 On-Hook Procedures
The on-hook procedures described in this section include:
• CID Mode
• Off-Hook Request
• Ring Detection and Line Voltage Reversal
• Line-in-use and Loss of Battery Feed
4.1 CID Mode
It is possible (while on hook) to allow the RGP/RGN input, which is AC coupled to the line through high
voltage capacitors, to be transmitted on the MAFE interface. This allows the host to listen for Caller ID
information without going off hook.
The registers used in this procedure are:
0x14
TXBST
DAA1
DAA0
Res
RXBST
RLPNH
RXG1
RXG0
Write
X
X
X
X
1
X
X
X
0x15
ENOLD
DISNTR
Res
CIDM
THEN
ENUVD
ENOVD
ENOID
Write
X
X
0
1
X
X
X
X
Begin
1. Set RXBST = 1 (Write RG14 = xxxx1xxx).
2. Set CIDM = 1 (write RG15 = xx11_xxxx).
End
CID Mode
RXBST =1
CIDM =1
End