5.2.7 M1X22_RING_DETECT_END

This event is generated when the driver detects the end of the ring burst.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1X22_RING_DETECT_END

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

Ring burst frequency (in Hz)

unsigned int

event_data2

Ring burst duration (in ms)

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.

5.2.8 M1X22_SYNC_LOSS_DETECT

This event is generated when the driver detects the failure of synchronization across the barrier path.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1X22_SYNC_LOSS_DETECT

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

N/A.

unsigned int

event_data2

N/A.

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.

5.2.9 M1X22_OV_DETECT

This event is generated on detection of an over voltage line condition.

Parameters

Data Type

Name

Description

unsigned int

event_id

M1X22_OV_DETECT

.

unsigned int

channel_id

Channel ID.

unsigned int

event_cnt

Number of events that remain in the queue.

unsigned int

event_data1

N/A.

unsigned int

event_data2

N/A.

unsigned int

event_data3

N/A.

unsigned int

event_data4

N/A.


Advertising