MIDI Solutions Event Processor User Manual

Page 5

Advertising
background image

5

TRIGGER MIDI EVENT

TURN SETTING ON/OFF

To program the Event Processor to trigger "MIDI Event B" when the specified values of "MIDI Event A" move into a
selected range, send it the following System Exclusive programming commands:

followed by

followed by

All bytes must be in Hexadecimal format (see hexadecimal conversion table at end)

= setting to be programmed (00 - 09)

specifies value ranges and variables (see description at end of instructions)

must contain at least one value range

cannot contain any value ranges.

and

combined can contain a maximum of 32 bytes.

To program setting #1 to trigger a middle C (Note-on #60) of velocity 127 on MIDI channel 1 whenever the value of
Control Change #7 on MIDI channel 1 moves above 63 (i.e. into the range 64 - 127), send the Event Processor the
following programming commands:

F0 00 00 50 28 03

F7

To program the Event Processor to turn a setting on or off when the value of "MIDI Event A" moves into a specified
range, send it the following System Exclusive programming commands:

followed by

All bytes must be in Hexadecimal format (see hexadecimal conversion table at end)

= setting to be programmed (00 - 09)

is set according to table below

= setting to turn On/Off (00 - 09)

specifies value ranges and variables (see description at end of instructions)

To program setting #1 to turn setting #10 ON when Control Change #64 on MIDI channel 1 is in the range 64 - 127,
and turn setting #10 OFF when the value is out of range, send the Event Processor the following programming
commands:

F0 00 00 50 28 06

F7

F0 00 00 50 28 03 ss (aa bb cc dd) F7

"MIDI Event A"

"MIDI Event B"

ss

(aa bb cc dd)

"MIDI Event A"

"MIDI Event B"

"MIDI Event A"

"MIDI Event B"

Example

00 01 03 40 7F

B0 07 00

90 3C 7F

F0 00 00 50 28 06 ss tt xx (aa bb cc dd) F7

"MIDI Event A"

ss

tt

xx

(aa bb cc dd)

Example

00 06 09 01 03 40 7F

B0 40 00

If value is out of range:

Turn setting ON

N/A

tt = 09
tt = 01

tt = 06

N/A

tt = 02

tt = 04
tt = 08

N/A

Turn setting ON

Turn setting OFF

Turn setting OFF

No action

No action

If value is in range:

Advertising