Specific safety rules specifications, Functional description, Symbology – Milwaukee Tool 6580-20 User Manual

Page 3: Read and save all instructions for future use, Extension cords

Advertising
background image

3

SPECIFIC SAFETY RULES

SPECIFICATIONS

Cat. No.

Volts AC

Amps

No Load RPM

6580-20
6740-20
6742-20
6780-20
6790-20
6791-20
6791-21
6792-20

120
120
120
120
120
120
120
120

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5

0 - 1200
0 - 2500
0 - 4000
0 - 2700
0 - 2500
0 - 2500
0 - 2500
0 - 2500

Hold power tool by insulated gripping sur-

faces, when performing an operation where
the fastener may contact hidden wiring or its
own cord.
Fasteners contacting a “live” wire may
make exposed metal parts of the power tool “live”
and could give the operator an electric shock.

Maintain labels and nameplates. These carry

important information. If unreadable or missing,
contact a MILWAUKEE service facility for a free
replacement.

WARNING: Some dust created by power sanding,

sawing, grinding, drilling, and other construction
activities contains chemicals known to cause
cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:

lead from lead-based paint
• crystalline silica from bricks and cement and
other masonry products, and
• arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending

on how often you do this type of work. To reduce
your exposure to these chemicals: work in a well
ventilated area, and work with approved safety
equipment, such as those dust masks that are spe-
cially designed to fi lter out microscopic particles.

FUNCTIONAL DESCRIPTION

Double Insulated

Amperes

Volts

Alternating Current

No Load Revolutions
per Minute (RPM)

Underwriters Laboratories, Inc.
United States and Canada

Mexican Approvals Marking

SYMBOLOGY

1

2

3

4

5

6

1. Locator
2. Ramp-off sleeve
3. Nameplate

7

8

9

4. Belt clip
5. Bit clip
6. Lock button
7. Trigger
8. Forward/Reverse switch
9. Gear case

Grounded tools require a three wire extension
cord. Double insulated tools can use either a two
or three wire extension cord. As the distance from
the supply outlet increases, you must use a heavier
gauge extension cord. Using extension cords with
inadequately sized wire causes a serious drop in
voltage, resulting in loss of power and possible tool
damage. Refer to the table shown to determine the
required minimum wire size.
The smaller the gauge number of the wire, the
greater the capacity of the cord. For example, a 14
gauge cord can carry a higher current than a 16
gauge cord. When using more than one extension
cord to make up the total length, be sure each cord
contains at least the minimum wire size required.
If you are using one extension cord for more than
one tool, add the nameplate amperes and use the
sum to determine the required minimum wire size.

Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be

sure it is marked with the suffi x “W-A” (“W” in Cana-
da) to indicate that it is acceptable for outdoor use.

• Be sure your extension cord is properly wired

and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a
qualifi ed person before using it.

• Protect your extension cords from sharp objects,

excessive heat and damp or wet areas.

READ AND SAVE ALL

INSTRUCTIONS FOR FUTURE USE.

* Based on limiting the line voltage drop to fi ve volts at

150% of the rated amperes.

EXTENSION CORDS

Recommended Minimum Wire Gauge

For Extension Cords*

Extension Cord Length

Nameplate

Amperes

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

18
18
18
18
16
14
12

18
18
18
16
14
12
10

18
18
16
14
12
10

--

18
16
14
12
10

--
--

16
14
12
12

--
--
--