8.3 Valve Block Mounting
Ensure that no hydraulic components will interfere with any sprayer parts or be
pulled tight at any time.
The recommended mounting location is on the rear of the boom main section
and on the vertical member centered below the Hardi valve block. Orient the
valve block such that the "A" and "B" ports face downward.
1. A suitable mounting location for the valve block is illustrated in Figure 19.
2. Insert the threaded rod into the block and use a hex nut to hold the rod. The block holes
are 3/8” NC-1” deep. If bolts are used instead of the threaded rod, ensure the bolts thread
in at least 3/8”.
3. Use the remaining hardware to secure the block to the sprayer.
4. Cut off excess threaded rod, if necessary.
Figure 19: Valve Block Mounting