7. Remove the plug from the Sense Line Bleed port. Location is shown in Figure 22. Gently
tap the plug with a hammer to loosen it before attempting to remove it.
8. Remove the Sense Line Bleed Orifice and discard. (Figure 22) Install the setscrew (F15)
into the Sense Line Bleed Orifice location. Ensure the setscrew is threaded entirely into
the hole and tightened to 35-40 in-lbs to ensure a tight seal. Reinstall the plug and tighten
to 35-40 in-lbs.
Figure 22: Load Sense Bleed Orifice Location on Top of Block