16
Figure 16: Cable Configurations: C03, C11, C12, C13 and C16
7. Connect the 3-pin tower (T3) on cable C16 to S3 on C11.
8. Insert the 2-pin tees (S2A-T2A - S2D-T2D) of C16 between the matching valve connections
(Left Up, Left Down, Right Up, Right Down) on the sprayer valve block.
9. Connect the 6-pin shroud on cable C12 to T6 on C11.
10. Insert the 2-pin tees (S2A-T2A and S2B-T2B) of C12 between the matching valve
connections (Main Up, Main Down) on the sprayer valve block.
11. Connect the 3-pin shroud (S3) on cable C13 to T3 on C11.
12. Insert the 2-pin tee of C13 between the bypass valve connection on the sprayer valve block.
Figure 17: Interface Wiring Depiction
Bypass
Left Up
Main Up
Right Up
Left Down
Main Down
Right Down